🎁 Final Month Special: 15% OFF + Free Shipping on Most Items! Don't Miss Out - Shop Now! ✨

Shopping Cart

Sub Total: $0.00
Total: $0.00
Checkout

Search Products

For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Image 1
View Media Gallery
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Image 2
View Media Gallery
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Image 3
View Media Gallery
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Image 4
View Media Gallery
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Image 5
View Media Gallery
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Nav Image 1
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Nav Image 2
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Nav Image 3
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Nav Image 4
For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case Nav Image 5

For Modbus RTU 8 Channel RS485 12V Relay Output Board Control Module Board +Case

$18.99 $21.99


Categories:

Hot sale
Estimated Delivery:
0 people are viewing this right now
Guaranteed Safe Checkout
Trust
Trust
  • Description

DIN rail box parameters:
  • Product model: UM72
  • Color: green
  • Width: suitable for circuit board width UM72 (inside 72)
  • Insulation grade: flame retardant VO grade
  • Base plate length: suitable for 10 cm circuit boards
  • Net weight: 72 grams
  • Installation method: DIM35 and C45 rail

Features:

  • Working voltage: DC 12V
  • Working current: standby 12MA, 1 relay conduction 40MA, 2 relay conduction 68MA, 3 relay conduction 94MA, 4 relay conduction 120MA, 5 relay conduction 148MA, 6 relay conduction 174MA, 7 Two relays conduct 199MA, 8 relays conduct 224MA
  • Open, close, jog, self-lock, interlock, and delay six working modes
  • MODBUS command (default) and AT command two command control modes
  • The maximum delay under MODBUS command is 255 seconds, the maximum delay under AT command is 9999 seconds
  • AT commands can be input by serial port super terminal (serial assistant); MODBUS commands can be input by "Modbus Poll" besides serial port super terminal input
  • In MODBUS command mode, up to 64 devices can be used in parallel
  • The default baud rate is 9600BPS, you can select the baud rate 2400 4800 19200 BPS through the jumper
  • Size: 100 * 72 * 20mm (circuit board); 120 * 88 * 42mm (with rail box)
  • Weight: 120g (circuit board); 198g (with rail box)
  • Maximum load: 10A/250VAC, 10A/125VAC, 10A/30VDC, 10A/28VDC, 10A/12VDC